ImageGear Professional v18.2 > User Guide > Using ImageGear > Scanning Images > Scanning Images Using the ISIS Interface > More ISIS Characteristics > Working with IG_ISIS_drv_load in Special Cases |
The PIXMISIS and FROMPIXM drivers will not work with the default parameters passed to them during the initialization routine used by IG_ISIS_drv_load_init_pipe(), and so they cannot be loaded, initialized, and linked by using this function. You must use separate
IG_ISIS_drv_load(), IG_ISIS_drv_init(), and IG_ISIS_drv_link() calls.
It is not safe to unload drivers without first unlinking them, and it is bad programming practice to do so. If a linked driver remains in memory and is used after its child or sibling is gone, the pipe is in an unstable state. The driver will forward its data to an undetermined location, causing unpredictable results.
Don't unload your drivers without first unlinking them! |